Skip to content

Vent-Trex Pre2021

Over-head extract fan / trickle ventilator
FOR USE ON PVCU, TIMBER OR ALUMINIUM WINDOWS

Overview

Vent-Trex is a unique combined overhead extract fan and trickle ventilator for kitchens and bathrooms that fits within the aperture on top of the window frame.

Vent-Trex is ideal for refurbishment situations where wall penetration is undesirable, as it does not damage the fabric of the building or where external aesthetics need to be preserved.

It provides a trickle ventilation performance Equivalent Area (EA) of 2500mm² minimum and extract ventilation rates to suit either kitchens or bathrooms.

Suitable for

  • PVCu
  • ALUMINIUM
  • TIMBER

Features & Benefits

  • Unique combined extract fan/trickle ventilator
  • Suitable for all window types
  • Integral with window, ideal for refurbishment situations
  • Avoids damage or penetration of building fabric
  • Easy to install
  • Saves wall space
  • Low installation costs compared to traditional extract ventilators
  • Bathroom version – single speed (15 l/s)
  • Kitchen version – two speed (60 l/s and 30 l/s)
  • 2500mm² EA minimum
  • Low energy usage
  • Easy to clean
  • Easy to maintain
  • IP24 rating
  • Pull cord switch and power light (dependant on model)
  • Humidistat option available (integral or remote)
  • Available with remote PSU (SELV) option for bathrooms
  • Continuous power or continuous running versions
  • Variable speed version
  • Suitable for use in conservation areas
  • 2-year guarantee

Technical Information

Technical Information

Details

Bathroom Fan Options Minimum length (mm) Minimum unit length to achieve stated airflow (mm) Airflow (l/s)
Standard Integral PSU + Pull Cord 420 520 15 *
Standard Remote PSU + Pull Cord 390 505 15 *
Standard Remote PSU + Ceiling Switch 290 405 15 *
Standard Integral PSU + Pull Cord + Humidistat 420 520 15 *
Standard Remote PSU + Pull Cord + Humidistat 390 505 15 *
Standard Remote PSU + Ceiling Switch (L) + Humidistat 390 505 15 *
Continuous Power Integral PSU + Pull Cord + Humidistat 420 520 15 *
Continuous Running Integral PSU + Pull Cord 420 520 8.6/11.8 *
Cord Control Integral PSU 420 520 15 *

* Single speed x Two speed

Details

Kitchen Fan Options Minimum length (mm) Minimum unit length to achieve stated airflow (mm) Airflow (l/s)
Standard Integral PSU + Pull Cord 450 1200 30/60 x
Standard Integral PSU + Ceiling Switch (L) 450 1200 30/60 x
Standard Integral PSU + Pull Cord + Humidistat 450 1200 30/60 x
Standard Integral PSU + Ceiling Switch (L) + Humidistat 450 1200 30/60 x
Continuous Power Integral PSU + Pull Cord + Humidistat 450 1200 30/60 x
Continuous Power Integral PSU + Ceiling Switch (M) + Humidistat 450 1200 30/60 x
Continuous Running Integral PSU + Pull Cord 520 1200 8.7/21.6 x
Cord Control Integral PSU 450 1200 30/60 x
Variable Speed Integral PSU 450 1200 30/60 x

* Single speed x Two speed

Configurations

Handing – pull cord and cable entry can be either on the left or right side (viewed from inside the property)
Flex entry to the unit can be either from the front or the end.

Optional Extras

Units can be supplied with or without external mesh.
Units can be supplied as permanent ventilators,
i.e. no slide (Not available for cord control units).

Meanings

Remote PSU
To provide extra low voltage capability for use in bathrooms SELV.
Standard
Pull cord or ceiling switch must be pulled to switch unit on and to allow humidity sensing to operate.
Continuous Power
Pull cord or ceiling switch manually operates the fan, unit will always respond to humidity change.
Continuous Running
Fan will run at low speed continuously and increase to the higher speed on pulling the pull cord.
Cord Control
The unit has two pull cords one each side.
One to open the slide, one to close the slide.
Also switching the unit on & off.
Variable Speed
Variable boost speed – used to reduce fan boost speeds in conjunction with open flued appliances, to avoid fumes being pulled back into property. (integral potentiometer adjustment).
Humidistat
Measures a change in humidity to trigger the fan to run or increase in speed.
Ceiling Switch
Momentary switch (M) – using pull cord to break contacts.
Latching switch (L) using normally open and common contacts.
Fitting, wiring and operation instructions are available, please contact Titon Technical Dept.

Performance

Equivalent Area (EA) – 2500mm² (minimum)
Free Area (mm2) – Bathroom model:
Integral PSU (length 520-2500mm): 5280mm² min
Remote PSU (length 405-2500mm): 5280mm² min
Kitchen model: Length 880-2500mm: 9000mm²

Details

230V AC Voltage / Power Consumption (standard version)
12V Bathroom – 3.95W @ 15 l/s (540mm length) (Integral PSU)
24V Kitchen – 21W @ 60 l/s (1200mm length) (Integral PSU)
Motor protection: IP24 Rating CE marked according to LVD and EMC directives

Finishes

White finish as standard to RAL 9010. Can be supplied in different colours. External canopy and internal fan can be coloured independently.

Details available on request.

Measuring

  1. VENT-TREX can be supplied for a ‘parallel’ (typically English) or a ‘check’ (typically Scottish) reveal, please refer to diagrams below.
  2. These are intended only as general illustrations. Specific installation details may vary & should always be checked on site prior to order.
  3. Allow for uneven reveals & check dimensions at more than one point.
  4. Allow for power cable if required to exit from end of unit.
  5. Round A & B measurements down to nearest 5mm increment i.e. 973mm will be 970mm after tolerance).

Required Measurements

A = External width (canopy width)
(Brick to brick or render to render)

B = Overall width of fan unit.
(Plaster face to plasters face)

D = Allowance for fitting (typically 5mm)

 

 

Documentation

Resources

Catalogues

Vent-Trex - Catalogue Page

814.89 KB (English)
Download

URL for Vent-Trex - Catalogue Page copied to clipboard.

Contact one of our experts

Whatever your query, please get in touch.